
Flexo Photopolymer Plate Making
FLEXO PHOTOPOLYMER PLATEMAKING MACHINE are distillers which allow the recycling and the re-use of degreasing and washing solvents.Through a simple distillation process, they separate the contaminants (resins, polymers, pigments, paints, oils, etc.) from the original solvent.The boiling of the solvent is accomplished by a peripheral heating jacket filled with diathermic oil, heated by an electrical element. The vapours are then convoyed to a condenser cooled by air or water. The condensed solvent is collected in a tank, for its reuse.
Used for :
FLEXO PHOTOPOLYMER PLATEMAKING MACHINE is used for recovery the waste solution resulting from the following: automobile manufacturing and repair industry; electronic products manufacturing industry; precision instruments and hardware manufacturing industry; sports equipment manufacturing industry; shoe material industry; plastic materials; printing industry; manufacture of chemical coatings; FRP products industry; jewelry industry; optical products; etc.
Applications :
Recovering Unit For Any Environment
Features of Exposure unit :
Instant light up Philips high intensity lampsUnique digital timers for back/main exposureExcellent lamps cooling /exhausting systemQuick vacuum drawdown pump with indicator
Features of Treatment unit :
Chemical free operation, simple, easy and saveDigital timer for light finishing controlPhilips UVC high intensity lamps equippedWith powerful air exhausting for big size models

Solvent Recovery Systems advantages :
- • Reduce your solvent disposal costs and wastewater treatment surcharges
- • 1 year or better payback on most solvent recycling
- • Equipment sized to meet the needs of small users, and the largest industrial plants.
- • With new, used, and refurbished options, we can usually find a system to fit your budget.
- • Technical help with setting up and training to use the solvent recycling systems
- • We won’t forget you after the sale.
# Operating steps
After opening the crate, plug in 220 V power, and connect the ground (earth).
Open the lid and fill the tank up to the level with solvent to be recovered (80 L) Close the lid and tighten it.
Check all the pipe / hose make sure it is well connected. Especially vacuum pipe (6) and fresh come-out pipe(1).
Set up the thermostat(18) for example for Perc.is 150 degree C, for green chemical is 160-210 degree C.
Vacuum tank pressure(3) high at 0.03 Mpa / low at 0.01Mpa, and steam cooling fan thermostat(11) at 40 degree C.
Turn on the power switch(15), steam cooling switch(16), heater switch(17) and vacuum pump switch(12).
If you want to be controlled with timer, it depends on the quantity of the chemical, set up the timer(14) then turn on the switch(13).
# Important
Install the unit in a wide and ventilated place
Disconnect electric power before doing any action
No taking off the control panel
Change the diathermic oil every 1000 working hours
No filling the solvent container up over the level (80 liters)
Remove the waste after every recovery process
Recovery Time 3 o 4 hours
Specifications & features subject to change without notice,Other size also available by special requested order.